ZEMIC-H3-100kg
http://www.zemic.com.vn LOADCELL ZEMIC BM14G Nickel plated alloy steel IP67 “S” type load cell Tension and compression applications. Also available in imperial capacities and dimensions Suitable for hanging, hopper and other weighing devices. in Viet Nam by TPS Scales Zemic
MODEL
|
H3
|
Maximum Capacity
|
100 kg
|
Accuracy class
|
OIML R60 C3
|
Output sensitivity
|
(2.0 ± 0.004) mV/V
|
Input resistance
|
(350 ± 3.5 ) Ω
|
Output resistance
|
(351 ± 2.0 ) Ω
|
Size loadcell
|
(76.2 x 50.8 x 19)mm
|
Production by
|
ZEMIC EURO
|
Distributor by
|
www.zemic.com.vn
|
Certificate
|
OIML , CE
|
Price:
2,200,000 VNĐ
Details
LOADCELL ZEMIC H3
1. H3 load cells are available in the capacities 25kg to 30t and 100lb to 20klb.
2. Alloy steel,sealed by adhesive inside,oil-proof,waterproof and anti-corrosion,suitable for all kinds of environments.
3. S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical
conversion scale, hopper scale and other electronic weighing devices.
4. Safe and anti-explosive product, can be used in atrocious environment and hazardous areas.
Specifications:
Capacity |
L |
H |
W1 |
W |
M |
H1 |
25~50㎏ |
76.2 (3.0) |
50.8 (2.0) |
12.7 (0.5) |
16.1 (0.63) |
M8 |
15.7 (0.62) |
0.1~1.5t |
76.2 (3.0) |
50.8 (2.0) |
19.0 (0.75) |
22.4 (0.88) |
M10×1.5 |
15.3 (0.60) |
0.2~0.75t |
76.2 (3.0) |
50.8 (2.0) |
19.0 (0.75) |
22.4 (0.88) |
M12×1.75 |
13.6 (0.54) |
1~1.5t |
76.2 (3.0) |
50.8 (2.0) |
25.4 (1.0) |
28.8 (1.13) |
M12×1.75 |
12.1 (0.48) |
2~5t |
101.6 (4.0) |
76.2 (3.0) |
25.4 (1.0) |
28.8 (1.13) |
M20×1.5 |
20 (0.79) |
7.5~10t |
175 (6.89) |
125 (4.92) |
50 (1.97) |
/ |
M33×3 |
40.2 (1.58) |
15~20t |
200 (7.89) |
160 (6.3) |
60 (2.36) |
/ |
M42×3 |
51 (2.01) |
30t |
230 (9.06) |
190 (7.48) |
80 (3.15) |
/ |
M42×3 |
57.5 (2.26) |
100~300lb |
63.5 (2.5) |
50.8 (2.0) |
12.7 (0.5) |
15.9 (0.63) |
1/4—28UNF |
10.1(0.4) |
500lb |
63.5 (2.5) |
50.8 (2.0) |
19.05 (0.75) |
22.25 (0.88) |
1/2—20UNF |
0.75~1.5klb |
63.5 (2.5) |
50.8 (2.0) |
19.05 (0.75) |
22.25 (0.88) |
1/2—20UNF |
2~2.5klb |
63.5 (2.5) |
50.8 (2.0) |
25.4 (1.0) |
28.6 (1.13) |
1/2—20UNF |
3klb |
101.6 (4.0) |
76.2 (3.0) |
25.4 (1.0) |
28.6 (1.13) |
1/2—20UNF |
15.24 (0.6) |
5~10klb |
101.6 (4.0) |
76.2 (3.0) |
25.4 (1.0) |
28.6 (1.13) |
3/4—16UNF |
15.24 (0.6) |
15klb |
139.7 (5.5) |
101.6 (4.0) |
31.75 (1.25) |
34.95 (1.38) |
1—14UNS |
31 (1.22) |
20klb |
177.8 (7.0) |
127 (5.0) |
50.8 (2.0) |
54 (2.13) |
5/4—12UNF |
39.9 (1.57) |
Specifications:
Capacity |
t |
0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/0.75/1/1.5/2/2.5/3/5/7.5/10/15/20/30 |
lb |
100/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K |
Accuracy |
|
C2 |
C3 |
C4 |
A5S |
A5M |
B10S |
B10M |
Approval |
|
|
OIML R60 C3 |
OIML R60 C4 |
|
|
|
|
Maximum number of verification intervals |
n max |
2000 |
3000 |
4000 |
5000 |
5000 |
10000 |
10000 |
Minimum load cell verification interval |
v min |
Emax /5000 |
Emax /10000 |
Emax /14000 |
Emax /15000 |
Emax /15000 |
Emax /10000 |
Emax /10000 |
Combined error |
%FS |
≤±0.030 |
≤±0.020 |
≤±0.018 |
≤±0.018 |
≤±0.026 |
≤±0.035 |
≤±0.050 |
Creep |
%FS /30min |
≤±0.024 |
≤±0.016 |
≤±0.012 |
≤±0.012 |
≤±0.017 |
≤±0.030 |
≤±0.040 |
Temperature effect on sensitivity |
%FS/10℃ |
≤±0.017 |
≤±0.011 |
≤±0.009 |
≤±0.009 |
≤±0.013 |
≤±0.030 |
≤±0.040 |
Temperature effect on zero |
%FS/10℃ |
≤±0.023 |
≤±0.015 |
≤±0.010 |
≤±0.010 |
≤±0.014 |
≤±0.030 |
≤±0.020 |
Output sensitivity |
mv/v |
2.0±0.004(Metric) 3.0±0.008(Imperial) |
Input resistance |
Ω |
350±3.5 |
Output resistance |
Ω |
351±2.0 |
Insulation resistance |
MΩ |
≥ 5000(50VDC) |
Zero balance |
%FS |
1.5(Metric) 1.0(Imperial) |
Temperature, compensated |
℃ |
-10~+40 |
Temperature, operating |
℃ |
-35~+65 |
Excitation, Recommended |
V |
5~12(DC) |
Excitation, Max |
V |
18(DC) |
Safe overload |
%FS |
150 |
Ultimate overload |
%FS |
300 |
Technical document