ZEMIC-L6E-50kg
http://www.zemic.com.vn LOADCELL ZEMIC L6E single point load cell, Aluminium-alloy IP65, Colourless anodized, Suitable for pricing scales, counting scales, bench scales, medical scales, etc. Maximum platform size: 400 x 400 mm.in Viet Nam by TPS Scales
MODEL
|
L6E
|
Maximum Capacity
|
50kg
|
Accuracy class
|
OIML R60 C3
|
Output sensitivity
|
2.0 ± 0.2 mv/V
|
Input resistance
|
( 406 ± 6 ) Ω
|
Output resistance
|
( 350 ± 3 ) Ω
|
Size loadcell
|
(150 x 35 x 40)mm
|
Production by
|
ZEMIC EURO
|
Distributor by
|
www.zemic.com.vn
|
Certificate
|
OIML , CE
|
Price:
1,250,000 VNĐ
Details
LOADCELL ZEMIC L6E
1. L6E load cells are available in the capacities 50kg to 300kg.
2. Aluminum construction with parallel beam.
3. Silicon adhesive sealed, surface anodized and anti-corrosion.
4. Intergral structure and easy installation.
5. Suitable for pricing scales, platform scales and other electronic weighing devices.
6. High accuracy.
7. Max. platform size: 400x400mm.
8. With OIML approval.
Specifications:
Capacity |
(kg) |
50/60/80/100/150/200/300 |
Accuracy |
|
C3D |
C3 |
C3G |
Approvals |
|
|
OIML R60 C3 |
|
Maximum number of verification intervals |
n max |
2500 |
3000 |
4000 |
Minimum load cell verification interval |
v min |
Emax/5000 |
Emax/7000 |
Emax/11000 |
Combined error |
(%FS) |
≤±0.030 |
≤±0.020 |
≤±0.015 |
Creep |
(%FS/30min) |
≤±0.020 |
≤±0.0167 |
≤±0.0125 |
Temperature effect on sensitivity |
(%FS/10℃) |
≤±0.021 |
≤±0.0175 |
≤±0.0131 |
Temperature effect on zero |
(%FS/10℃) |
≤±0.028 |
≤±0.020 |
≤±0.0127 |
Output sensitivity |
(mv/v) |
2.0±0.2 |
Input resistance |
(Ω) |
406±6 |
Output resistance |
(Ω) |
350±3 |
Insulation resistance |
(MΩ) |
≥5000(50VDC) |
Zero balance |
(%FS) |
2 |
Temperature,compensated |
(℃) |
-10~+40 |
Temperature,operating |
(℃) |
-35~+65 |
Excitation, Recommended |
(V) |
5~12(DC) |
Excitation,Max |
(V) |
18(DC) |
Safe overload |
(%FS) |
150 |
Ultimate overload |
(%FS) |
300 |
Corner correction |
|
0.02% load value/100mm |
Technical document